TC-R1 trace cable for PICE-52 emulator
- Intends to trace external signals from the target and to output syncronization impulses
- The PICE trace cable allows to enter up to 8 external signals, status of which can be recorded to the real time trace buffer
- Status of each traced signal can be used as a condition for breaking the emulation of generation of the trigger impulse
- Trigger outputs can be used for sinchronization of logic analyzers, oscilloscopes and other lab equipment
- Cables are about 10" (25 cm) long and has 14 micro grabbers for hooking control points on the target
- Two green micro grabbers are intended to connect the Ground, 8 black - for entering and 2-4 red - for outputting the signals